nav emailalert searchbtn searchbox tablepage yinyongbenwen piczone journalimg journalInfo journalinfonormal searchdiv searchzone qikanlogo popupnotification paper paperNew
2017, 04, v.17;No.100 1348-1353
基于Pyrosim的宿舍楼火灾模拟分析
基金项目(Foundation): 广东省自然科学基金项目(S2013010016748)
邮箱(Email):
DOI: 10.13637/j.issn.1009-6094.2017.04.028
发布时间: 2017-08-25
出版时间: 2017-08-25
移动端阅读
摘要:

为研究不同火灾工况对宿舍楼火灾过程的影响,应用Pyrosim对某大学东六宿舍进行火灾动态模拟,对比分析了宿舍大楼所有门窗全开状态和着火房间窗户闭合、门在20 s后打开的状态下,宿舍楼各部分温度、烟气层高度、门窗热流量及烟气蔓延特点。Pyrosim模拟结果表明,在火灾爆发的前20 s内,火势发展与门窗开合状态无关。在火灾中后期,门窗全开状态下,着火房间的温度及热流量较低、烟气层离地的高度较高,着火房间上方的宿舍受烟气影响较为严重;而在着火房间窗户闭合、门在20 s后打开状态下,横向走廊及各层楼梯处受烟气影响较严重。

Abstract:

This paper is inclined to bring about an analysis of likely-to-be existing factors to cause the dormitory fire risks by taking No. 6 Dormitory of a certain university as a case study sample. In the paper,we have illustrated such factors of the building fire as the temperature,the smoke layer height,the heat flow,and the smoke movement in two different conditions with all the windows and doors being open,or with the windows closed but the doors opened 20 seconds later after the fire broke out. In doing so,we have also set up two conditions according to the two general situations of the students' dormitories( with the students living in at night for sleep and with them engaged in some daily activities). The results of the Pyrosim simulated research indicate that there doesn't seem to have any correlation or correlations be-tween the fire appearance and the two conditions mentioned above during the first 20 s since the fire broke out. And,later,when the doors and windows are opened,high temperature areas of the stairs would come into the room whereas the overall temperature in the dormitory remains lower and the smoke thickness begins to rise abruptly. Comparing the conditions with the windows closed and the door opened 20 s later,the high temperature area of the stairs would become spread over the upper space. Moreover,when the fire broke out,part of the violent heat may tend to propagate through the doors and windows. In such a situation,most of the heat would spread and propagate the high temperature of the fire to the firing room. Furthermore,with the aggravation of the fire disasters,the heat flow from the door and the accumulated heat flow in the firing room may turn to become much lower than that situation with the windows closed and the doors opened 20 s later. Thus,in the whole process,the upper stories of the fire building would be seriously suffered by the smoke in case the windows and doors of the firing room were opened. In contracts,the corridors and stairs would be more seriously affected by the smoke when the room windows in fire are closed with the door opened 20 seconds later.

参考文献

[1]GAO Ran,LI Angui,HAO Xinpeng,et al.Fire-induced smoke control via hybrid ventilation in a huge transit terminal subway station[J].Energy and Buildings,2012,45:280-289.

[2]AYALA P,CANTIZANO A,GUTIERREZ M C,et al.Influence of atrium roof geometries on the numerical predictions of fre tests under natural ventilation conditions[J].Energy and Buildings,2013,65:382-390.

[3]SHEN T S,HUANG Y H,CHIEN S W.Using fre dynamic simulation(FDS)to reconstruct an arson fre scene[J].Building and Environment,2008,43:1036-1045.

[4]LAI C M,CHEN C J,TSAI M J,et al.Determinations of the fre smoke layer height in a naturally ventilated room[J].Fire Safety Journal,2013,58:1-14.

[5]HADJISOPHOCLEOUS G,JIA Q.Comparison of FDS prediction of smoke movement in a 10-storey building with experimental data[J].Fire Technology,2009,45:163-177.

[6]HE Mingli(何明礼),LIU Juan(刘娟),ZHAO Hao(赵浩).Fire simulation of tenglong students’dormitory[J].Journal of Hubei Polytechnic University(湖北理工学院学报),2015,31(1):12-16.

[7]GLASA J,VALASEK L,WEISENPACHER P,et al.Cinema fire modelling by FDS[J].Journal of Physics:Conference Series,2013,410(1):1-4.

[8]LIANG Junhai(梁君海),LI Xia(李霞),LIN Jianhui(林建辉),et al.Analyses of EMU fire based on Pyro Sim[J].Journal of Chongqing University of Technology:Natural Science(重庆理工大学学报:自然科学版),2014,28(10):35-37.

[9]SHANG Chao(尚超),WANG Keyin(王克印),HUANG Haiying(黄海英),et al.Forest trees in fire modeling research based on the Pyro Sim[J].Fire Science and Technology(消防科学技术),2013,32(9):1030-1033.

[10]LIU Qiankun,GAO Ye,CHOW Wanki,et al.Numerical studies on kitchen fire hazards with multiple burning sources[J].Building Simulation,2015,8:453-463.

[11]CHOWA W K,ZOU G W.Numerical simulation of pressure changes in closed chamber fres[J].Building and Environment,2009,44:1261-1275.

[12]ZHANG Guowei,ZHU Guoqing,YIN Fei.A whole process prediction method for temperature field of fire smoke in large spaces[J].Procedia Engineering,2014,71:310-350.

[13]HOROVA K,JANA T,WALD F.Temperature heterogeneity during travelling fre on experimental building[J].Advances in Engineering Software,2013,62:119-130.

[14]JIANG Zemin,ZHANG Peihong,SHANG Rongxue,et al.Investigation and simulation on human evacuation behaviour in large hospital building in Shenyang[J].Procedia Engineering,2014,71:101-106.

[15]CHEN F,CHIEN S,LEE Y,et al.The integrated strategies for fire safety of long road tunnels in Taiwan[J].Procedia Engineering,2013,62:36-45.

[16]MENG Na,HU Longhua,WU Long,et al.Numerical study on the optimization of smoke ventilation mode at the conjunction area between tunnel track and platform in emergency of a train fre at subway station[J].Tunnelling and Underground Space Technology,2014,40:151-159.

[17]CUI Teijun(崔铁军),MA Yundong(马云东).FDS-based fire simulation and evacuation plan for subway station in course of construction[J].Journal of Natural Disasters(自然灾害学报),2013,22(6):178-184.

[18]LUTHER W,MULLER W C.FDS simulation of the fuel freball from a hypothetical commercial airliner crash on a generic nuclear power plant[J].Nuclear Engineering and Design,2009,239:2056-2069.

[19]OZTEKIN E S.Heat and mass transfer due to a small-fre in an aircraft cargo compartment[J].International Journal of Heat and Mass Transfer,2014,73:562-573.

[20]Occupant Evacuation Behaviour and Condition BSI Group.The application of fire safety engineering principles to fire safety design of buildings,BSI PD7974-6[R].London:Occupant Evacuation Behaviour and Condition BSI Group,2004.

基本信息:

DOI:10.13637/j.issn.1009-6094.2017.04.028

中图分类号:TU998.1

引用信息:

[1]龙新峰,张雪琴,楼波.基于Pyrosim的宿舍楼火灾模拟分析[J].安全与环境学报,2017,17(04):1348-1353.DOI:10.13637/j.issn.1009-6094.2017.04.028.

基金信息:

广东省自然科学基金项目(S2013010016748)

发布时间:

2017-08-25

出版时间:

2017-08-25

检 索 高级检索