nav emailalert searchbtn searchbox tablepage yinyongbenwen piczone journalimg journalInfo journalinfonormal searchdiv searchzone qikanlogo popupnotification paper paperNew
2004, S1, 50-54
设计火灾时火灾热释放速率曲线的确定
基金项目(Foundation):
邮箱(Email):
DOI:
发布时间: 2004-12-30
出版时间: 2004-12-30
移动端阅读
摘要:

在运用火灾计算机模型进行建筑物性能化消防设计与评估时,确定合理、切合实际的火灾的热释放速率曲线非常重要。基于当前国内外的研究现状,本文提出了几种符合当前技术水平且实用的确定火灾热释放速率曲线的方法,对于每种分析计算方法及其适用条件进行了详细阐述,并给出了相关的计算实例。

Abstract:

Heat release rate is one of the most important parameters in the process of fire development. It is essential to determine correct and reasonable heat release rate curve when conducting performance-based fire safety design with fire simulation model. Unfortunately, no combustion model is included in most fire models since it is still an enormous challenge to simulate the combustion process of fire based on the current technology. This paper attempts to find some applicable methods which can help model users to determine heat release rate curve by themselves. According to some research results of a china's 10th 5-year plan key research project named "technical guideline on the performance-based fire safety design" and some experience got from some case studies of performance — based fire safety design, several practical methods are presented to determine the heat release rate curve in different situations which can represent the realistic fire scenario. The applicability of each method is also discussed. A set of examples are illustrated at the same time.

参考文献

[1] Vytenis Babrauskas. Heat Release Rate, SFPE Handbook of Fire Protection Engineering [M]. 2nd ed. Quincy: National Fire Proection Association, 2002

[2] Website of National Institute of Science and Technology:http: //www. fire. nist. gov /fire / fires / work2 /work2. html

[3] Edward K Budnick, Harold E Nelson and David D Evans.Simplified Fire Growth Calculations, Fire Protection Handbook [M]. 18th ed. Quincy: National Fire Protection Association,1997

[4] Fire Code Reform Center Limited. Fire Engineering Guidelines [R]. 1996

[5] NFPA 204-2002. Standard for Smoke and Heat Venting[S]

[6] ISO/WD 16733 Fire Safety Engineering-Selection of design fire scenarios and design fires. Nov 2003.

[7] British Standard, Fire Safety Engineering in Buildings[S], BS DD240: 1997.

[8] Evans D D and Stroup D W. Methods to calculate the response time of heat and smoke detectors installed below large unobstructed ceilings[J]. Fire Technology, 1986, 22: 54~65

[9] McCaffrey B J, Quintiere J G and Harkleroad M F. Estimating room temperatures and the likelihood of flashover using fire test data correlations [J]. Fire Technology, 1981, 17: 98~119

[10] Friedman R. Quantification of threat from a rapidly growing fire in terms of relative material properties [J]. Fire and Materials, 1978, 1: 27~33

基本信息:

中图分类号:X932

引用信息:

[1]王志刚,倪照鹏,王宗存,姜明理.设计火灾时火灾热释放速率曲线的确定[J].安全与环境学报,2004(S1):50-54.